ODA (ONE-DROP ANALYSIS)


PRODUCT COMPARISON

ACCUSENSING

Glassy Carbon Electrode

Spectrophotometer

Colorimetric Kits

Test Time

1~5 mins 40~90 mins 5~15 mins 5 mins

Reagents-free

Y N N Y

Calibration-free

Y N N Y

Digital read-out

Y Y Y N

Price/test

3~10 USD Depends on test qty. 3~8 USD <2 USD

REVOLUTION OF THREE ELECTRODES SYSTEM

最傳統的電化學方法,每一支電極(工作電極、輔助電極、參考電極)皆是獨立運作,再根據實驗需求進行搭配。

    The three electrodes (WE, CE, RE) are independently separated. As the working electrode, glassy carbon electrode (GCE) is adopted, requiring a complex surface modification and pre-treatment procedure before use.



最傳統的電化學方法,每一支電極(工作電極、輔助電極、參考電極)皆是獨立運作,再根據實驗需求進行搭配。

最傳統的電化學方法,每一支電極(工作電極、輔助電極、參考電極)皆是獨立運作,再根據實驗需求進行搭配。

    We have started to implement the screen-printed technology for our electrodes, using cost-effective screen-printed electrodes (SPE) as the working electrode. These electrodes are disposable, offering a more affordable solution.



最傳統的電化學方法,每一支電極(工作電極、輔助電極、參考電極)皆是獨立運作,再根據實驗需求進行搭配。

最傳統的電化學方法,每一支電極(工作電極、輔助電極、參考電極)皆是獨立運作,再根據實驗需求進行搭配。

    By employing the screen-printed technology, we have successfully integrated the three separate electrodes onto a single substrate. This approach allows for flexible electrode design, significantly enhancing the sensitivity of our analyses.


最傳統的電化學方法,每一支電極(工作電極、輔助電極、參考電極)皆是獨立運作,再根據實驗需求進行搭配。

最傳統的電化學方法,每一支電極(工作電極、輔助電極、參考電極)皆是獨立運作,再根據實驗需求進行搭配。

    We have incorporated blood glucose test strip technology, establishing microchannels on the screen-printed electrodes and coating them with reagents. This transformation simplifies the once complex analytical process, achieving detection precision at the parts per billion (ppb) level.



FAQ

  • Do users add reagent by themselves before measuring?

    No. Each strip from ACCUSENSING is already pre-coated by reactive reagent on the microfluidic channel. There are two ways to make the sample fill the microfluidic channel to react with the reagent: (1)use a dropper to draw the sample then drop a drop of sample on the triangle entrance of the strip; (2)dip the strip to the sample for 1-2 sec(s). to siphon the water to the microfluidic channel. The precoated reagent differs from different kind of strip, ACCUSENSING is able to well develop the optimized reagent for each kind of strip owing to the huge electrochemistry research results accumulated since 1995. In order to create a stable analysis environment in the tiny space, the precoated reagent had been continuously tested and modified by our R&D team to ensure the reproducibility and accuracy.

  • Do users quantify the sample before measuring?

    No. Each strip is manufactured in batch production to unify the volume of microfluidic channel on the strip. To fulfill the quantification, users only need to fill the microfluidic channel by following either one method in Q1.

  • Do users calibrate the calibration curve before measuring?

    No, each batch of strips have been calibrated in factory already. The calibration curve is preinstalled in the smart chip. In order to ensure each batch of strips fits the calibration curve, the strips are tested through a series of process to verify the accuracy and precision.